Fixed Gas & Flame Detection

SB100 Ultrasonic Bump Tester

SB100 Ultrasonic Bump Tester

The SB100 is a hand-held battery-operated rechargeable ultrasonic tester designed to bump test General Monitors ultrasonic gas leak detectors. The SB100 is useful for quick tests where physical access to the ultrasonic gas detector can be difficult. The unit can be used to bump test up to 18 meters away from the detector in Class 1, Div 1&2 hazardous areas.
Ultima® Controller

Ultima® Controller

The Ultima Controller is purpose-designed and built to provide complete access to all advanced features of the Ultima and Ultima X Gas Monitors, as well as the Toxgard II Gas Monitor. Via its full-function and password-protected keypad, users can set the real time clock, set alarm levels, change span-gas values, display date of last calibration, display minimum, maximum and average gas values, change address and set future calibration time/date in addition to providing basic calibration functions
MSA Ultima Series XE Gas Detector

Ultima® X Series Gas Monitors

Designed to provide thorough, continuous monitoring of many hazardous gases, the indoor/outdoor Ultima X Series Gas Monitors offer excellent performance and MSA quality craftsmanship. DuraSource™ Technology offers extended sensor life, while HART provides convenient setup, calibration and diagnostics. HART also allows for existing component install and wiring to be used. A single circuit board increases reliability, while our patented sensor disconnect-underpower feature allows all sensors to be replaced in hazardous areas without area declassification. The units are crafted from either stainless steel or polycarbonate, and the interchangeable smart sensors eliminate the need for reconfiguration. Our scrolling LCD screen display sensor reading and gas type, while the calibration process includes date stamping and the ability to calibrate locally or remotely.
FlameGard® 5 MSIR Flame Detector

FlameGard® 5 MSIR Flame Detector

MSA's FlameGard® 5 MSIR Detector is an advanced multi-spectrum flame detector designed to provide superior false alarm immunity with the widest field of view. The detector employs a state-of-the-art multi-spectrum infrared (MSIR) sensor array with a sophisticated Neural Network Technology (NNT) system.
Ultima® Calibrator

Ultima® Calibrator

The Ultima Calibrator offers the industry's simplest, quickest calibration. Simple, three-button device is purpose-built for calibrating and changing the address of Ultima and Ultima X Gas Monitors and the Toxgard II Gas Monitor.
SM5000 Sampling Module

SM5000 Sampling Module

Built for safety programs that demand gas concentration measurement before allowing entrance to an area, the SM5000 Sampling Module is exclusively designed to work with the Ultima X5000, Ultima XE and General Monitors S5000 gas monitors. The unit features an explosion-proof design and reliably extracts a sample from any confined or inaccessible area—or any area that is too hot, cold, or otherwise harsh—and delivers gas concentration reading directly to the installed gas monitor.
MSA FL3100H UV/Infared Flame Detector

FL3100H UV/IR Flame Detector

The FL3100H is an Ultraviolet / Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It monitors in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed locally.
Zero Two Series Gas and Flame Detection System

Zero Two Series Gas and Flame Detection System

Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection. In addition, its open architecture allows the system to accommodate other sensing devices for tasks such as smoke detection, heat detection and manual call points. 
TA102A Single Channel Combustible Trip Amplifier Module

TA102A Single Channel Combustible Trip Amplifier Module

The TA102A is a single-channel Combustible Gas Trip Amplifier Module designed for use with one General Monitors intelligent transmitter to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through a front panel interface (mode / select switch and digital display). A digital display indicates fault codes and set up options. Other features include: LED indications of status, as well as both open collector and relay outputs for fault, low alarm and high alarm.
4802A Zero Two Series Control Module for Combustible Applications

4802A Zero Two Series Control Module for Combustible Applications

The 4802A is a single channel Combustible Gas Control Module that has been designed for use with our proven catalytic bead sensors. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through the front panel interface. A digital display indicates gas concentration, fault codes, calibration cues and setup options. Other features: LED indications of status, as well as open collector and relay outputs.