Fire & Gas Systems

Zero Two Series Gas and Flame Detection System

Zero Two Series Gas and Flame Detection System

Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection. In addition, its open architecture allows the system to accommodate other sensing devices for tasks such as smoke detection, heat detection and manual call points. 
TA102A Single Channel Combustible Trip Amplifier Module

TA102A Single Channel Combustible Trip Amplifier Module

The TA102A is a single-channel Combustible Gas Trip Amplifier Module designed for use with one General Monitors intelligent transmitter to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through a front panel interface (mode / select switch and digital display). A digital display indicates fault codes and set up options. Other features include: LED indications of status, as well as both open collector and relay outputs for fault, low alarm and high alarm.
4802A Zero Two Series Control Module for Combustible Applications

4802A Zero Two Series Control Module for Combustible Applications

The 4802A is a single channel Combustible Gas Control Module that has been designed for use with General Monitors catalytic bead sensors. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through the front panel interface. A digital display indicates gas concentration, fault codes, calibration cues and setup options. Other features: LED indications of status, as well as open collector and relay outputs.
CC02A Serial Communications Module

CC02A Serial Communications Module

The CC02A Communications Card facilitates serial communications between each module in a Zero Two Series Flame and Gas Detection System and an external host computer, which allows fast access to operational and setup data registers. It supports a Burst Read feature that returns all registers of a module in a single transmission.
FM002A Facilities Module

FM002A Facilities Module

The FM002A is a facilities module that provides a range of common facilities for all Zero Two control modules housed in the chassis. The FM002A is plugged into the last slot on the right-hand side of the Zero Two chassis. It may be daisy-chained allowing one FM002A to serve up to 100 Zero Two modules in any combination.
IN042 Four Zone Control Module

IN042 Four Zone Control Module

The IN042 is a four zone input module designed for use with two-wire field devices such as smoke or heat detectors, pull switches and manual callpoints. It is designed to monitor these devices and provide both status indication and fault / alarm outputs for each zone.
Discontinued DT210 Eight Channel H2S Readout / Relay Module

DT210 Eight Channel H2S Readout / Relay Module

The DT210 is an eight-channel Readout / Relay Module designed for use with up to eight of our remotely located H2S Intelligent Sensors. The front panel contains a digital display that indicates 0-20 ppm (parts per million), 0-50 ppm, or 0-99 ppm of the hydrogen sulfide gas monitored by the Intelligent Sensors.
Discontinued MD002 Monitored Driver Output Module

MD002 Monitored Driver Output Module

The MD002 is a monitored driver output module designed for four independent outputs requiring monitoring in their non-active state, such as extinguishing solenoids, beacons, horns, etc. Each driver is independent and has circuitry to monitor short and open circuits in field wiring.
Discontinued ZN002A Three Zone Control Module

ZN002A Three Zone Control Module

The ZN002A is a Zone Control Module for the Zero Two Series Fire and Gas Detection System. The ZN002A provides zoning and voting functions for three separate and independent zones of gas and / or flame detection.
Select up to 3 items to compare Compare (0)