Kits de calibração e acessórios

Fixed Gas Detector Accessories

Fixed Gas Detector Accessories

There are many accessories available for the Ultima X5000 and General Monitors S5000 Gas Monitors to enhance the functionality of your gas detection system including junction boxes, calibration equipment and sensor accessories.
Ultima® Controller

Ultima® Controller

O módulo ULTIMA CONTROLLER é um dispositivo de comunicação portátil que permite a calibração e configuração dos detectores de gases da série Ultima, Ultima X e Toxgard II. O ULTIMA CONTROLLER é a melhor opção para o usuário que deseja, além da calibração do equipamento, ter acesso a todas as funções avançadas do mesmo. 
Ultima® X Sampling Module

Ultima® X Sampling Module

Built for safety programs that demand gas concentration measurement before allowing entrance to an area, the SM5000 Sampling Module is exclusively designed to work with the Ultima X5000, Ultima XE and General Monitors S5000 gas monitors. The unit features an explosion-proof design and reliably extracts a sample from any confined or inaccessible area—or any area that is too hot, cold, or otherwise harsh—and delivers gas concentration reading directly to the installed gas monitor.
Catalytic Bead Accessories

Catalytic Bead Accessories

General Monitors offers a wide variety of accessories for our catalytic bead gas sensors.
IR Gas Detector Accessories

IR Gas Detector Accessories

General Monitors offers a wide variety of accessories for infrared gas leak detection.
H2S Gas Sensors and Accessories

H2S Gas Sensors and Accessories

General Monitorsʼ hydrogen sulfide (H2S) sensors are solid state devices, designed and manufactured for long life and fast response. They are selective to H2S and remain unaffected by high concentrations of other substances like hydrogen, sulfur dioxide, and gasoline vapors, which are often present in facilities that process sour gas and crude oil. A high tolerance to a broad range of temperatures and humidity enable these sensors to operate in rugged environments, as does their capacity to withstand exposure to high H2S concentrations over short periods.
Sensores Eletroquímicos de Gás

Sensores Eletroquímicos de Gás

Os sensores eletroquímicos de gás da General Monitors são altamente sensíveis aos gases tóxicos incluindo monóxido de carbono, H2S, hidrogênio, cloreto de hidrogênio, amônia, cloro, dióxido de cloro, óxido nítrico, dióxido de nitrogênio, ozônio, SO2 e deficiência de oxigênio.
Toxic Gas Accessories

Toxic Gas Accessories

General Monitors offers a wide variety of accessories for our toxic gas detectors.
RGC - Remote Gas Calibrator for Catalytic Bead Sensors

RGC - Remote Gas Calibrator for Catalytic Bead Sensors

The Remote Gas Calibrator (RGC) allows calibration gas to be applied to a remotely located catalytic bead sensor from an easily accessible location. The RGC is used for blocking ambient air and redirecting methane to the catalytic sensor for calibration or testing sensor accuracy. The RGC tests or calibrates the General Monitors catalytic sensor with 50% LEL methane. The unit is capable of calibrating gas at wind velocities up to 50 mph. The RGC is used manually with a pressure regulator (P/N 80146-1) and is suitable for calibrating with any light hydrocarbon.
RGC-IR - Remote Gas Calibrator for Point IR Detectors

RGC-IR - Remote Gas Calibrator for Point IR Detectors

The remote gas calibrator, RGC-IR, is designed to be permanently installed on a combustible IR gas detector. The RGC-IR provides protection from outside elements and allows the user to apply calibration gas (@ 50 psi) to the detector from a remote source.
RGC-HT - Remote Gas Calibrator for High Temperatures

RGC-HT - Remote Gas Calibrator for High Temperatures

To verify the proper operation of a catalytic combustible gas sensor, it is necessary to periodically apply a gas of known concentration to the sensor. This is usually done manually at the site with gas supplied from a small lecture bottle. As the sensor reacts to the calibration gas, adjustments are made to the monitoring system to bring its calibration into agreement with the known concentration of the calibration gas. At times, sensors are mounted in inaccessible locations, requiring expensive catwalks or scaffolding to reach them. The High Temp Remote Gas Calibrator (RGC-HT) allows the calibration gas to be applied to the catalytic bead sensor from easily accessible locations. The RGC-HT is used for blocking ambient air and redirecting methane or other light hydrocarbon gases to the catalytic bead sensor for calibration or testing sensor accuracy in various environments. The RGC-HT tests or calibrates the General Monitors Catalytic Bead sensor with 50% LEL methane or other light hydrocarbon gas. The unit is capable of calibrating and detecting gases in various wind conditions (up to 45 mph) and temperatures (up to 200°C when used with high temperature sensor).
Mounting Hardware

Mounting Hardware

General Monitors offers a complete line of mounting hardware to facilitate installing any of our gas and flame detectors in commercial or industrial facilities.